This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
en:0003:tds [07/10/2017 16:19] fran [0003·TDS ~ Temperature sensors] |
en:0003:tds [07/10/2017 18:55] (current) fran [0003·TDS ~ Temperature sensor] |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | FIXME **This page is not fully translated, yet. Please help completing the translation.**\\ //(remove this paragraph once the translation is finished)// | + | ====== 0003·TDS ~ Temperature Sensor ====== |
| - | ====== 0003·TDS ~ Temperature sensor ====== | + | ===== Description ===== |
| - | ===== Descripción ===== | + | The module **0003·TDS** is specially designed for measuring temperatures in the range |
| + | -55 ° C ~ 125 ° C, especially suitable for temperature monitoring | ||
| + | in low temperature ovens and preservation processes. | ||
| - | El módulo **0003·TDS** es un equipo especialmente diseñado para la medida de temperaturas en el rango | ||
| - | -55ºC ~ 125ºC, especialmente indicado para la monitorización de la temperaturas en hornos de baja temperatura | ||
| - | y procesos de conservación. | ||
| - | Se basa en un [[https://datasheets.maximintegrated.com/en/ds/DS18B20.pdf|chip]] monolítico que nos ofrece una resolución de 0,07ºC con un error en la banda de -10ºC a 85ºC de (+-)0,5ºC | + | It is based on a monolithic [[https://datasheets.maximintegrated.com/en/ds/DS18B20.pdf|chip]] that offers a resolution of 0,07ºC with an error in the range of -10° C to 85° C (+-)0.5° C. |
| - | ===== Parámetros ===== | + | ===== Parameters ===== |
| - | ^ Parámetro ^ Mínimo ^ Típico ^ Máximo ^ Unidad ^ | + | ^ Parameter ^ Minimum ^ Typical ^ Maximum ^ Unit ^ |
| - | | Rango Temperatura | -55 | | 125 | ºC | | + | | Temperature Range | -55 | | 125 | ºC | |
| - | | Error de Medida (-10~85ºC) | | | (+-)0,5 | ºC | | + | | Measurement Error (-10~85ºC) | | | (+-)0,5 | ºC | |
| - | | Error de Medida (-55~125ºC) | | | (+-)2,0 | ºC | | + | | Measurement Error (-55~125ºC) | | | (+-)2,0 | ºC | |
| - | ===== Conexionado ===== | + | ===== Connections ===== |
| - | {{ 0003:ds18b20_bulb.jpg?300}}{{0003:tds.svg }} Las sondas de medida de este dispositivo son del tipo [[https://datasheets.maximintegrated.com/en/ds/DS18B20.pdf|DS18B20]], su alimentación es de 3,3V y se comunican con el equipo a través de un único cable, en la imagen puede ver una de las sondas que suministramos con el dispositivo. | + | {{ 0003:ds18b20_bulb.jpg?300}}{{0003:tds.svg }} The measuring probes of this device are of the [[https://datasheets.maximintegrated.com/en/ds/DS18B20.pdf|DS18B20]] type, its power is 3.3V and communicate with the equipment through a single cable, in the image you can see one of the probes that we supplied with the device. |
| - | El bornero auxiliar dispone de las bornas de alimentación, gnd y positivo, y de la borna de comunicaciones con la sonda. | + | The auxiliary terminals has the power supply terminals, gnd and positive, and terminal communications with the probe. |
| - | Hay que prestar especial atención en la conexión, debe ser lo mas estable posible, el cable de conexión será de una medida inferior a los 3 metros y el elemento de medida, el chip, debe estar protegido ante los agentes climatológicos. | + | Particular attention must be paid to the connection, it must be as stable as possible, the connection cable will be less than 3 meters and the measuring element, the chip, must be protected from weather agents. |
| - | ===== Puesta en Marcha ===== | + | ===== Startup ===== |
| - | ===== Configuración ===== | + | ===== Configuration ===== |
| - | ===== Uso ===== | + | ===== Use ===== |