This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
en:0003:main [07/10/2017 17:11] fran [Conexionado] |
en:0003:main [07/10/2017 18:18] (current) fran [Description] |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | FIXME **This page is not fully translated, yet. Please help completing the translation.**\\ //(remove this paragraph once the translation is finished)// | ||
| - | |||
| ====== 0003 · Generic Automation Module ====== | ====== 0003 · Generic Automation Module ====== | ||
| Line 10: | Line 8: | ||
| The size of the module is that of a box of 140x45x29 mm with the typical format of power supply for LED lighting, this format provides a simple and direct installation in false ceilings, channels, large boxes or directly attached to the wall. | The size of the module is that of a box of 140x45x29 mm with the typical format of power supply for LED lighting, this format provides a simple and direct installation in false ceilings, channels, large boxes or directly attached to the wall. | ||
| - | On the cover of the box we will have both the model and the LEDs for signaling the status of the module, there is no external pushbutton so in case of a need to restart we will have to disconnect the equipment from the power supply. | + | The box cover indicates the model and there are a series of LEDs for signaling the status of the module, there is no external pushbutton so in case of a need to restart we will have to disconnect the equipment from the power supply. |
| Most equipment has a relay output, this relay can perform **direct** actions depending on the analog or digital reading of the module. | Most equipment has a relay output, this relay can perform **direct** actions depending on the analog or digital reading of the module. | ||
| Line 49: | Line 47: | ||
| The device has two terminals on both sides of the housing, covered by protective covers, in one of them is the power terminal, with only 2 terminals, and on the opposite side the auxiliary terminal, with several connectors depending on the model . | The device has two terminals on both sides of the housing, covered by protective covers, in one of them is the power terminal, with only 2 terminals, and on the opposite side the auxiliary terminal, with several connectors depending on the model . | ||
| - | ==== Borna Alimentación ==== | + | ==== Power Terminal Block ==== |
| - | La borna de alimentación (la de 2 bornes) es a través de la que tendremos que alimentar el dispositivo. Existen 2 versiones del dispositivo, la de alimentación a corriente alterna, con entrada de 100~240v y la versión de tensión continua con una entrada de 10~24v. | + | The power supply terminal (2 terminals) is through which we will have to power the device. There are 2 versions of the device, the AC power supply, with 100 ~ 240V input and the DC version with a 10 ~ 24V input. |
| - | Son **dos modelos totalmente distintos** no se puede alimentar la versión ''DC'' mediante alimentación en alterna, destruiría el equipo y este perdería la garantía. | + | They are **two totally different models**, you can not feed the '' DC '' version through AC power, it would destroy the equipment and it would lose the warranty. |
| - | === Versión AC === | + | === AC Version === |
| - | {{0003:ac.svg }} Para la versión AC, en el esquema podemos ver como conectaremos a ambas bornas sin importar la disposición. | + | {{0003:ac.svg }} For the AC version, in the diagram we can see how we will connect to both terminals regardless of layout. |
| - | === Versión DC === | + | === DC Version === |
| - | {{0003:dc.svg }} En la versión DC por el contrario, si que existe una disposición de los cables de alimentación que se debe respetar, si no se respetan el equipo no funcionará y por tanto no estará activo. | + | {{0003:dc.svg }} In the DC version, on the other hand, if there is an arrangement of the power cables that must be respected, if they are not respected the equipment will not work and therefore will not be active. |
| - | ==== Borna Auxiliar ==== | + | ==== Auxiliary Terminal ==== |
| - | {{0003:conrelay.svg }} La mayoria de los dispositivos cuentan con un relé conmutado con el que podemos comandar cualquier elemento con la borna auxiliar. | + | {{0003:conrelay.svg }} Most of the devices have a switched relay with which we can control any element with the auxiliary terminal. |
| - | En esta borna esta presente el contacto conmutado del relé. | + | In this terminal is present the switched contact of the relay. |
| - | {{0003:condef.svg }} El dispositivo base incorpora 2 entradas digitales en su configuración por defecto. | + | {{0003:condef.svg }} The base device incorporates 2 digital inputs in its default configuration. |
| - | Estas entradas son para contactos libres de tensión | + | These inputs are for voltage-free contacts. |
| - | ===== Puesta en Marcha ===== | + | ===== Sartup ===== |
| - | Para la puesta en marcha utilice el metodo descrito aqui: [[http://avftechnology.com/start.php|Proceso de Configuración]] | + | For startup use the method described here: [[http://avftechnology.com/start.php|Configuration Process]] |
| - | ===== Configuración ===== | + | ===== Configuration ===== |
| - | Todo el proceso de configuración esta descrito [[aqui]] | + | The entire configuration process is described [[here]]. |
| - | ===== Uso ===== | + | ===== Use ===== |